Lampu emergency

General Description of Lampu Emergency:
The Max-Lite Series is ideal for locations where
oil, water, and dust resistant equipment are required.
The Max-Lite Series is UL listed for use in damp
and wet locations with temperatures ranging from
32° F ( 0° C) to 104° F ( 40° C) . Practical installations
where the Max-Lite Series excels consist of
manufacturing facilities, parking decks, warehouses,
water treatment facilities and the like.
Equipped with Intelli-Charge, the Max-Lite Series
is provided standard with an on-board IR receiver
and is pre-programmed for use with our optional
hand held test device allowing for remote testing in
accordance with all applicable building code
requirements. One-minute and 90-minute testing
may also be initiated via the push to test switch on
the unit.
The Intelli-Charge circuit is a continuous,
real-time diagnostics circuit allowing for precise
equipment readiness indications via the dual
colored LED indicator. This indicator feature also
serves as the AC power, charge status and mode of
operation indicator for immediate recognition of the
equipment operating state. The standard diagnostics
function is enabled without the optional self-testing
in order to provide the highest level of equipment
readiness and for use in areas where unscheduled
transfer testing is not desired. Microprocessor
controlled temperature compensation is equivalent
to 3mV/ C° , optimizing the useful life and readiness
of the battery. The Max-Lite Series meets the Buy
American requirements.
Dimensions
Max-Lite Series
Hostile Environment Emergency Lighting
6 and 12 Volt, 25 to 150 Watts
Standard Self-Diagnostics Electronics*
Housing
Constructed of impact resistant, fiberglass reinforced
polyester, the housing color is gray and includes
stainless steel hardware. The view-through window
allows easy monitoring of the optional voltmeter and
ammeter. Available with NEMA rated polycarbonate
sealed beam Par 36 tungsten or halogen lamp heads.
Optional shatter-resistant shield for lamp heads is
designed for use in food service areas.
Intelli-Charge Diagnostic
Electronics ( standard)
120/ 277 VAC dual voltage input with surge protection
is standard on all models. Charging system is
microprocessor driven with software embedded
diagnostic routine and precision temperature
compensation. See specification sheet C1059 for
technical specifications for the electronics. Surge
protection, brownout, AC lockout, and low voltage
disconnect features are standard.
Intelli-Charge
Self-Testing Diagnostics
( optional)
The Intelli-Charge diagnostic/ charging platform with
self-testing mode automatically runs a one-minute
self-test every 30 days and a 30-minute test on the sixth
and twelfth month. A one-minute or 90-minute test may
be initiated via the push to test switch on the unit or by
activating the appropriate test command on the optional
IR test device.
Warranty
Three year full electronics warranty. One year full plus
four year prorated lead calcium battery warranty. Five
year full plus five year prorated nickel cadmium battery
warranty.
Battery
Maintenance free, sealed lead calcium battery has an
estimated service life of 5 years and an operating
temperature range of 32° F ( 0° C) to 104° F ( 40° C) .
Maintenance free, sealed nickel cadmium battery has
an estimated service life of 10 years and an operating
temperature range of 32° F ( 0° C) to 104° F ( 40° C) .
Batteries supply 90 minutes of emergency power.
Code Compliance
UL 924 listed
UL damp and wet location listed 32° F ( 0° C) to
104° F ( 40° C)
NFPA 70 and NFPA 101, NEC, BOCA, OSHA and
IBC illumination standards
NSF Standard 2 “ Splash Zone”
Electrical Specifications
Input power requirements
6 Volt
25-50W - 0.157A ( 120VAC) , 0.069A ( 277 VAC)
75W - 0.222A ( 120VAC) , 0.094A ( 277 VAC)
12 Volt
50-100W - 0.289A ( 120VAC) , 0.135A ( 277 VAC)
125W - 0.433A ( 120VAC) , 0.188A ( 277 VAC)
150W - 0.470A ( 120VAC) , 0.203A ( 277 VAC)
TYPE:
CATALOG NO.:
Shown: MN25ZV2IC
Ordering Information ( Example: MN25ZV2IC)
FACTORY INSTALLED
OPTIONS2
A = Ammeter
BD = Battery Disconnect Switch
EX = Special Input Transformer ( specify voltage & frequency)
F1 = 120 VAC Fuse
F2 = 277 VAC Fuse
P1 = 120 VAC Power Switch
P2 = 277 VAC Power Switch
S = Shatterproof Lexan Lamp Head Lens
T = Self-Testing Diagnostics
TA = Audible Self-Testing Diagnostics
TD = Time Delay ( 15 minutes)
V = Voltmeter
NOTES:
1) For self-testing models refer to options. 2) Some option combinations may impact UL listing. Consult factory for specifications.
ACCESSORIES
( order as a separate line item)
ICIR = Intelli-Charge Infra-Red Remote
WG = Wire Guard
Dimensions are approximate and subject to change.
SERIES/ BATTERY LAMP HEADS # OF HEADS
Blank = No Lamp Heads
1 = One Lamp Head
2 = Two Lamp Heads
3 = Three Lamp Heads
Chloride Systems is a Philips group brand
IC
MODEL
DESIGNATOR1
IC = Intelli-Charge
Diagnostic
Electronics
6 Volt, Tungsten
ZM = 8 Watts
ZN = 18 Watts
ZO = 25 Watts
6 Volt, Halogen
ZU = 8 Watts
ZV = 12 Watts
12 Volt, Tungsten
ZQ = 12 Watts
ZR = 18 Watts
ZS = 25 Watts
12 Volt, Halogen
ZW = 8 Watts
ZX = 12 Watts
Z5 = 50 Watts
Z5F = 50 Watts,
Flood
6 Volt, Lead Calcium
MC25 = 25 Watt Unit
MC50 = 50 Watt Unit
MC75 = 75 Watt Unit
6 Volt, Nickel Cadmium
MN25 = 25 Watt Unit
MN50 = 50 Watt Unit
MN75 = 75 Watt Unit
12 Volt, Lead Calcium
MTC50 = 50 Watt Unit
MTC75 = 75 Watt Unit
MTC100 = 100 Watt Unit
MTC125 = 125 Watt Unit
MTC150 = 150 Watt Unit
12 Volt, Nickel Cadmium
MTN50 = 50 Watt Unit
MTN75 = 75 Watt Unit
MTN100 = 100 Watt Unit
MTN125 = 125 Watt Unit
MTN150 = 150 Watt Unit
* Self-powered models incorporate the Intelli-Charge diagnostics
electronics package. Self-testing is a factory installed option.
15.2”
( 38.6 cm)
13.2”
( 33.5 cm)
21.4”
( 54.4 cm)
7.1”
( 18.0 cm) Specification Data for Max-Lite Series Hostile Environment Emergency Lighting Units
Suggested Specification
Furnish and install Chloride Systems’ Max-Lite Series emergency lighting unit model ___________________. The unit shall be listed to Underwriter' s Laboratories,
Inc. standard 924 and meet all applicable standards in the National Electrical Code ( NEC) , International Building Code ( IBC) as well as all state and municipal
requirements. The unit shall be UL wet location listed standard for use in areas with temperatures ranging from 32º F ( 0º C) to 104º F ( 40º C) . Additional listings shall
include NSF standard 2 " Splash Zone " .
INSTALLATION AND OPERATION - The unit shall be easily field connected to a 120 or 277 VAC, 60 Hz, unswitched power source. Installation must comply with the
NEC as well as other applicable codes. Upon utility power failure or brownout, the unit shall automatically to battery power and maintain the required illumination level
for a minimum period of not less than 90-minutes at the coldest rated temperature of the unit without the need to de-rate the capacity of the equipment. Upon
restoration of utility power, the charging system shall restore the battery to full charge within UL 924 requirements following a complete discharge cycle of the unit.
ELECTRONICS - The equipment shall be provided with Chloride' s Intelli-Charge electronics system. Intelli-Charge will detect and notify the installer of incorrect wiring
of the transformer primary and restrict any damaging effects from reaching the printed circuit board. The Intelli-Charge electronics shall provide continuous, real-time
monitoring of all the critical equipment functions including, but not limited to: line voltage status and condition, charger fault, transfer fault, battery fault, and load loss
detection to 10% of all connected loads. A visual indicator provides fault notification with the option to add an audible alarm as well. The optional self-testing software
shall satisfy the periodic testing requirements in NFPA 101, Life Safety Code as well as the International Fire Code ( IFC) . The Intelli-Charge with self-testing option
automatically runs a one-minute test every 30 days and a thirty minute test on the sixth and twelfth month. The Intelli-Charge system shall employ temperature
compensation which continuously samples the ambient temperature and adjusts the charging system for typical and dramatic temperature fluctuations at a rate equal to
3mV/ Cº to maximize the life and readiness of the batteries. An on-board IR receiver shall be standard and pre-programmed to operate from an optional hand-held IR
test device ( available as an accessory item) .
BATTERY - The battery shall be either maintenance-free sealed lead calcium or nickel cadmium type. The nickel cadmium battery shall utilize sintered plate
construction and polypropylene separators for trouble-free operation in ambient temperatures up to 104º F ( 40º C) and be tested and approved under IEC standard
61951-1. The lead calcium battery shall provide trouble-free operation in temperatures up to 104º F ( 40º C) .
HOUSING - The housing shall be constructed of impact-resistant, fiberglass reinforced polyester. Internal or external mounting feet shall be provided standard. The unit
shall be UL wet location listed.
C1007R22
12/ 10 IH
272 West Stag Park Service Road • Burgaw NC 28425
Telephone: ( 910) 259 1000 • Facsimile: ( 800) 258 8803
www.chloridesys.com
* The optics layout shown is intended to be used as reference only. Standard reflectances used were 80/ 50/ 20. Chloride is not responsible for site specific conditions that may alter the results.
Average initial footcandles at floor = 1.12
Maximum initial footcandles at floor = 4.9
Minimum initial footcandles at floor = 0.2
Maximum to minimum ratio = 24.50
Optics* ( IES formatted files are available on-line)
Wall Mounted 7.5' AFF, 12V 12W Halogen Lamp Heads Represented
2.
8.
2.2
2.7
9.
1.0
2.3
2.7
8.
2.
2.
8.
2.8
2.2
9.
9.
2.4
2.6
7 .
2.
3.
1.3
2.1
3.1
8.
8.
1.9
3.3
1.3
3.
3.
1.3
3.1
2.0
8.
7.
1.9
3.2
1.3
2.
2.
4.
5.
6.
5.
5.
5.
6.
5.
2.
2.
4.
6.
5.
5.
5.
5.
6.
4.
.2 9 ft.
7.5 ft.
30 ft.
1 FC Average
Average initial footcandles at floor = 2.97
Maximum initial footcandles at floor = 6.6
Minimum initial footcandles at floor = 1.0

Jumlah Pesanan: Tambah ke Keranjang
Cara Pembayaran:Transfer Bank (T/T)
Negara Asal:Amerika Serikat



Kontak Perusahaan
Nama:Tn. laberman@cbn.net.id 0815-9120-877 [Pemasaran]
E-mail:
Situs Web:
Pesan Instan:
Y!: pt.laberman@yahoo.com Y!: pt.laberman
Nomor Ponsel:Nomor ponsel Tn. laberman@cbn.net.id 0815-9120-877 di JAKARTA
Nomor Telpon:Nomor telpon Tn. laberman@cbn.net.id 0815-9120-877 di JAKARTA
Nomor Faks:Nomor faks Tn. laberman@cbn.net.id 0815-9120-877 di JAKARTA
Alamat:Perkantoran Taman Meruya Blok M 80,Jl Batu Mulia Raya
JAKARTA 11620, Jakarta
Indonesia
Alamat Tervalidasi
menampilkan 268 dari 299 | Sebelum : Lampu emergency light.... | Berikut : Hubbell Duallite outdoor....


Membuat situs langsung jadi?
Silahkan Klik disini!